Should the radiator in the same room as the thermostat have a TRV?

Why two thermostats controlling one room fight each other, what happens to the rest of the house, and the conventional answer.

Difficulty
beginner
Time
15 min
Read
3 min

Short answer

No. The radiator in the room with the room thermostat should have no TRV, or a TRV left fully open. Two controls on one room work against each other: the TRV closes the radiator, the room cools, the thermostat calls for heat, and the whole house heats while that room stays cold.

A room thermostat measures one room and controls the whole boiler. A TRV measures one room and controls one radiator. Put both in the same room and you have two devices trying to control the same temperature with completely different consequences.

How a programmer, a room thermostat and a TRV work together

Step by step

  1. Find where the room thermostat is.Usually a hallway, a landing or a living room. That room is the reference for the entire heating system.
  2. Check what valve is on that room's radiator.A thermostatic head with numbers means a TRV. A plain cap on both ends means it has none, which is what you want.
  3. Understand the conflict.If the TRV shuts that radiator, the room cools, and the thermostat keeps calling for heat. The boiler runs, every other room overheats, and the reference room never satisfies.
  4. Set it fully open if a TRV is fitted.The simplest fix. Turn it to maximum and leave it there permanently, so the room thermostat is the only control acting on that room.
  5. Consider removing the head altogether.Replacing the thermostatic head with a plain cap or a manual head removes the temptation to adjust it and makes the intent obvious to anyone else in the house.
  6. Check the thermostat is not next to a heat source.Above a radiator, in direct sun or beside a lamp, it satisfies early and the whole house is cold. That is a separate and equally common fault.
  7. Keep at least one radiator without a TRV.Most systems need a path for the water when everything else has closed. The thermostat room's radiator conventionally serves that purpose.
  8. Reconsider if you have smart valves.A full smart TRV system with a compatible controller manages this by coordinating the valves with the boiler demand. In that case the usual rule does not apply — follow the system's instructions.
  9. Check the results over a few days.Every other room should now reach temperature at a similar time to the thermostat room, and the boiler should cycle less.

Tips

  • If you take the head off, fit a plain cap so the valve stays clean and nobody tries to adjust it.
  • The thermostat room is the room that decides for the whole house. Where it sits matters more than any TRV setting.
  • Never fit a TRV to a radiator in a room where you also want the boiler to be controlled from — the two cannot both win.

Common mistakes

  • Turning down the TRV in the hall to save money — The hall thermostat then never satisfies and the boiler runs continuously, heating every other room. It costs more, not less.
  • Putting a TRV on every single radiator — If they all close, the pump is running against a closed system. Most installations need at least one radiator or a bypass permanently open.

If it doesn't work

Hall cold, rest of house too warm

Cause: TRV closing the hall radiator while the thermostat calls — Fix: Open the hall TRV fully or remove the head.

Boiler runs constantly and never satisfies

Cause: Thermostat room never reaching temperature — Fix: Same cause; also check the thermostat is not on a cold external wall.

House heats unevenly since fitting TRVs

Cause: TRV fitted in the reference room — Fix: Remove or fully open that one and rebalance if needed.

Pump noise when all rooms are up to temperature

Cause: Every valve closed with no bypass — Fix: Leave one radiator without a TRV, or have an automatic bypass valve fitted.

Questions people ask

Which radiator should not have a TRV?

The one in the room containing the room thermostat. It gives the thermostat an honest reading of the room and keeps a flow path open when every other valve closes.

What if my thermostat is in the hall and the hall gets too hot?

Move the thermostat rather than throttling the radiator, or fit a smart system that controls rooms individually. Throttling the hall radiator breaks the control logic for the whole house.